Find Power Group-Generator, Engine, Diesel Generator on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Ungrouped > Factory price 600Kva genset, powered by Cummins KTA19-G8 engine

Factory price 600Kva genset, powered by Cummins KTA19-G8 engine

Basic Info

Model No.: KTA19-G8

Product Description

600Kva genset (KTA19-G8)

 

Main technical data

 Cummins Engine

 

Every generator set is subjected to a comprehensivetest program which includes 50% load, 75% load,100% load, 110% load and the checking and proving of all control and safety shut-down functions;

24V DC start motor;

Equipped with battery charger and 24V highperformance maintenance-free lead-acid startingbatteries and connecting with cables;

Equipped with industrial silencer and flexible exhaust hose;

Equipped with CHINT MCCB circuit breaker;

Designed to Comply with ISO8528/GB2820;

Powered by Cummins engine,Controlled by Deepsea panel

 

Voltage

HZ

Phase

P.F

(COS)

Output

(KVA)

400/230V

50

3

0.8

600

Remark

60Hz, 220, 380V, 460V, 480V, 600V can be produced as requirements.

Engine

Cummins 600Kva Diesel Generator engine data

Engine Model

KTA19-G8

Number of Cylinders

6 cylinders, Vertical in line

Cycle

4 stroke

Aspiration

Turbocharged and after water cooled

Bore×Stroke

159mm x159mm

Displacement

18.9L

Compression ratio

13.9:1

Standby Power/Speed

575KW / 1500rpm

Speed Governor

electrical

Cooling System

Forced water cooling cycle

Steady speed droop

1%

Total lubrication system capacity

50L

Coolant capacity (engine only)

30L

Fuel Consumption at 100% Load

128L

Starter Motor

DC24V,

Alternator

AC24V

Alternator

 

Alternator brand

Stamford, Marathon, Leroy Somer, Mecc-alte, TWGII…

Prime power

600Kva

Frequency/speed

50HZ/1500rpm (60Hz/1800rpm)

Exciter type

Single bearing, Brushless, Self-excited

Power factor

0.8

Voltage adjust range

5%

Voltage regulation NL-FL

≤±1%

Insulation Grade

H

Protection Grade

IP23

Control panel

The control module gives digital readouts of:

Generator voltage;

Output frequency;

Engine speed;

Battery voltage;

Engine hours run.

The control module has indicators for failure

information:

Overspeed/underspeed,

Emergency stop

Low oil pressure;

High water temperature

Failure to start

Battery charger failure

Automatic shutdown occurs under:

Low engine oil pressure;

High engine water temperature;

Overspeed/underspeed;

Failure to start after three attempts.

 

Pictures FYI

600Kva Cummins diesel generator

 

 

 

 

 

 

600Kva Cummins diesel generator (Packing)

 

Contact us

Sutech Power Co., Ltd

No.18 Hailing Industry Park, Taizhou City, Jiangsu Province, China

Mobile: +86-15161006661

Tel: +86-523-86282985

Skype: stmeco

G-talk: sutech.power

Product Categories : Ungrouped